Linc Energy Blog

With the attitude of “let’s not blow it – good planets are hard to find,” the Linc Energy Blog is writing about energy. We’ll explore alternative energy and conventional energy. We’re interesting in providing an outlet to voice thoughts on bridging fossil fuels like natural gas to alternative energy.

Viewing entries from Susan
Susan

Susan

Susan Bender started selling to the natural gas industry in 1980. In 1990 she founded Linc Energy Systems, where she remains as President and CEO. She attributes her success to her philosophy, “The customer is king (or queen),” which remains part of her company’s mission.

Blog entries tagged in tracer wire

Corrosion proof tracer wire connectors

by Susan
Susan
Susan Bender started selling to the natural gas industry in 1980. In 1990 she f
User is currently offline
Wednesday, 06 July 2011 Category Damage Prevention 0 Comments

Tracer wire manufacturers routinely strive for advancements to prevent situations where tracer wire fails. Recently Copperhead Industries introduced a new product, corrosion proof tracer wire connectors which minimize connection failure while backfilling, provide corrosion protection and save time and money.

In an earlier blog post “What makes utilities and pipelines locatable?” I mentioned that without a carbon or low allow-steel pipeline, utility workers have come to rely on tracer wire to locate utilities and pipelines.

In this case, the underground tracer wire is installed next to a pipeline and made accessible at various access points like manholes, valve boxes, vaults, or other enclosed access devices. When the tracer wire is charged at an access point a magnetic field will provide a signal the locator can use with ground penetrating radar (GPR) or electromagnetic pipe detection (EPD) equipment. The locating wire makes non-locatable lines (made of polyethylene, plastic, fiberglass or concrete) locatable when they remain intact.

Unfortunately tracer wire or direct burial wire is not flawless and there are a few common reasons wire typically fails:

  • The common material used in tracer wire is copper. Unfortunately, copper is expensive which has made tracer wire prone to theft and you can’t trace a line if it’s not there!
  • Copper wire is inflexible and can break during installation and a broken line won’t carry the current.
  • Many tracer wires have vinyl or nylon coatings which fail prematurely when the line is exposed to moisture.

To address these common weaknesses, manufacturers like Copperhead Industries have introduced tracer wire breakthroughs which include: corrosion resistance, stronger and more durable tracer wire (Copperhead steel clad) and less expensive alternatives to copper.

Recently, Copperhead Industries, a leading tracer wire manufacturer has introduced SnakeBite tracer wire connectors demonstrating another step forward. The new connectors require no wire stripping. By inserting the wires into the SnakeBite openings and simply turning 90 degrees the tracer wire connector is locked shut, giving the installer peace of mind that the connectors won’t unlock while backfilling the line. With no reason to strip wire, installers require fewer tools and save time. What makes this new connector even more unique is the dielectric water proof and corrosion proof sealant inside the SnakeBite connector. The connectors are color-coded by industry with 3 APWA colors: yellow-natural gas, blue-water, orange-telecom.


More information on Copperhead Industries and the new corrosion proof connectors can be found onour  Pipeline Excavation Products page.

 

Tags: natural gas inustry, ground penetrating radar, GPR, tracer wire, locating utilities, electromagnetic pipe detection, EPD, gas distribution lines, corrosion control
Read More Hits: 1071
Rate this blog entry
19 votes

What makes utilities and pipelines locatable?

by Susan
Susan
Susan Bender started selling to the natural gas industry in 1980. In 1990 she f
User is currently offline
Tuesday, 08 February 2011 Category Damage Prevention 0 Comments

Pipeline corrosion and digging by third party individuals or contractors are among the two leading causes of pipeline accidents. In earlier posts, I’ve discussed the significance of protecting pipelines against corrosion. I also discussed the importance of calling 811 to locate the utility lines before digging. But calling 811 does not always guarantee your lines will be located, which made me wonder what makes pipelines and facilities locatable?

In Colorado, when calling 811 you will be arranging to have what is known as “Tier 1” utilities located. The 811 organization for Colorado is UNCC and they will additionally provide the excavator with contact information for Tier 2 utilities that are in your area, and it is the responsibility of the excavator or homeowner to call those Tier 2 utilities to request a locate.

After locators have arrived, sometimes the excavator or homeowner learns that their lines can’t be located. This usually raises frustrations and questions.

What makes a line locatable?

Most utility locating equipment uses a technology known as ground penetrating radar (GPR). Others may refer to it as electromagnetic pipe detection (EPD). This science is based on the principal that an electrical current will flow along a conductive material, creating a magnetic field which can be received as a signal, and indicate the presence of a pipeline by location equipment.


Most gas or oil transmission lines use carbon or low alloy-steels. These lines will generate a magnetic field when charged so that the lines can be detected. However, gas distribution lines are commonly polyethylene (PE) and will not carry a current. Therefore the line will not be locatable by itself, unless a tracer wire was installed at the time of pipeline installation.


In this case, tracer wire is installed next to a pipeline and made accessible at various access points like manholes, valve boxes, vaults, or other enclosed access devices. When the tracer wire is charged at an access point a magnetic field will provide a signal the locator can use with GPR /EPD equipment. Tracer wire makes non-locatable lines (made of polyethylene, plastic, fiberglass or concrete) locatable when they remain intact.

While tracer wire offers an effective way to trace a line, the system is not flawless. Some well-known reasons tracer wire fails are:

  • The common material used in tracer wire is copper. Unfortunately, copper is expensive which has made tracer wire prone to theft and you can’t trace a line if it’s not there!
  • Copper wire is inflexible and can break during installation and a broken line won’t carry the current.
  • Many tracer wires have vinyl or nylon coatings which fail prematurely when the line is exposed to moisture.

Due to these common weaknesses, tracer wire manufacturers have been challenged to introduce alternatives.  Some product advancements include: corrosion resistance, superior strength and durability, and cost expensive alternatives to traditional copper tracer wire.

What makes utilities and pipelines locatable? Without a pipeline being constructed with conductive material or a line installed with tracer wire the line locator is left with line-of-sight locating which is highly subject to error.

 


 

Tags: call before you dig, 811, UNCC, damage prevention, locating utilities, tracer wire, ground penetrating radar, GPR, electromagnetic pipe detection, EPD, gas distribution lines
Read More Hits: 1086